anthony.sanchez@LIGO.ORG - posted 15:58, Saturday 08 February 2025 - last comment - 12:49, Sunday 09 February 2025(82700)
Lockloss from 8.0 Mag Earthquake

When verbals announced an earthquake I checked the SEI screen the earthquake was listed as an 8.0 Mag!

I then quickly checked USGS and they also had listed it as an 8.0 Mag but it seems like it has since been demoted to a 7.6?
https://earthquake.usgs.gov/earthquakes/eventpage/us7000pcdl/executive

When it struck all the ISI's trip before verbals could finish announcing the earthquake.
I immidiately called Jim and ask him if I should hit the very large Earthquake button, but he said if things were already tripped then it doesn't really matter.




 

 

Images attached to this report
Comments related to this report
brian.lantz@LIGO.ORG - 12:49, Sunday 09 February 2025 (82707)

Here's a plot of the peak velocity as reported by Peak_mon at LLO and LHO. The start time is the time of the EQ, per USGS.

Looks like about 300 microns/sec peak at Hanford and 500 microns/sec peak in Livingston. yikes

Images attached to this comment