OPS Eve Shift Start

TITLE: 02/13 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 13mph Gusts, 7mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.23 μm/s
QUICK SUMMARY:

IFO is LOCKING at ENGAGE_ASC_FOR_FULL_IFO

Some ALS Locking issues as we were locking, thought to be due to recent table work that required new TRX gain normalization, which conflicted with ALS Gurardian Scan Alignment. The gain of 3.0 (up from 1.5) has been temporarily accepted in the SAFE.snap temporarily until more tuning is done tomorrow (attached SDF).

Images attached to this report