Reports until 19:28, Friday 25 October 2013
H1 SUS
arnaud.pele@LIGO.ORG - posted 19:28, Friday 25 October 2013 - last comment - 10:13, Thursday 31 October 2013(8279)
ETMX and SRM measurements

I will start transfer functions of top mass of main and reaction chain of ITMX phase 3a (in chamber, under vacuum) on computer opsws2 and top mass phase 2b SRM (test stand) on computer opsws0 from 8pm tonight.

Measurements will run until saturday morning. Please do not close those matlab sessions if you come over the week end.

The channel list used to get the data from the framebuilder (in generate_channel_list.m living in sus/trunk/Common/Matlabtools/SchroederPhaseTools) has been modified to match with the recent model upgrade of the QUADS. Since channels H1:SUS-${QUAD}_${L1/L2}_DAMP_${DOF}_IN1_DQ do not exist any more. They are now called H1:SUS-${QUAD}_${L1/L2}_WIT_${DOF}.
This is related to why we couldn't get data out of the frame for the ETMX on thursday
This is also related to why we couldn't see any good calibrated rotation signal with dataviewer on ETMX for the UIM and the PUM

Comments related to this report
arnaud.pele@LIGO.ORG - 10:13, Thursday 31 October 2013 (8333)

I ment ITMX in the title