H1 Back to Observing

H1 back to observing at 16:47 UTC following a small-ish ETM glitch lockloss at 14:47 UTC. Fully automatic relock with an initial alignment.

After some time at NLN, I noticed the DCPD sums growing and traced it to ETMY violin mode 20 ringing up. Turning off the gain (nominally -1.0) stopped it from rising. After 15 minutes or so, I tried just a sign flip for the gain (so, 1.0) and so far that seems to be damping the mode down. Will keep an eye on this today. [OpsInfo]

Comments related to this report
ryan.short@LIGO.ORG - 09:35, Friday 14 February 2025 (82803)

Also had to accept SDF diffs for alsey. Corey had accepted these in reverse last night (alog82798), but trending the swstat for these filters, FM9 (a -14dB filter) is nominally OFF, hence my acceptance. Looks like it was turned on towards the end of an initial alignment, but not sure yet why.