Reports until 18:57, Friday 14 February 2025
H1 SEI (Lockloss)
ibrahim.abouelfettouh@LIGO.ORG - posted 18:57, Friday 14 February 2025 - last comment - 20:21, Friday 14 February 2025(82821)
Lockloss 02:33

Lockloss due to 5.7 EQ in Mongolia. Initially I thought we rode it out since the EQ happened since verbal sounded it 30 minutes before losing lock. Though looking at the later arriving R waves, we seem to have lost lock 3 minutes after they were detected by ISI Sensors, microseism FOM and Picket Fence. Right after the LL, EQ mode activated. High secondary microseism likely contributes to higher EQ susceptibility too.

Shall begin to re-lock once it passes.

Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 20:21, Friday 14 February 2025 (82822)

Back to OBSERVING as of 04:19 UTC