TITLE: 02/16 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: One lockloss this shift at the end of calibration sweeps and H1 has been trying to relock since. [OpsInfo] I've put new damping settings for ETMY mode 20 into the Guardian and loaded; these have been working well the past couple of days.
- 19:30 - Dropped observing for scheduled calibration sweeps - alog82827
- 20:01 - Lockloss at end of sweeps
- Went immediately into initial alignment, ran automatically
- Been a long relock due to two locklosses at TRANSITION_FROM_ETMX and lots of random dropouts during ALS, FIND_IR, and DRMI with no clear causes. Microseism has been higher this afternoon, but generally alignment has been good and signals have looked stable