oli.patane@LIGO.ORG - posted 21:50, Sunday 16 February 2025 - last comment - 20:22, Monday 17 February 2025(82847)
Small set of strange locklosses over the weekend

I was looking at the lockloss sheet and noticed that this weekend, there were three locklosses that were similar to each other. Ryan Short noted one in an alog a couple days ago: 82809.

The locklosses look similar to what we sometimes see when we lose lock due to ground motion from an earthquake or wind, but in all three cases there was no earthquake motion, and the wind was below 20mph. There will be an 11 Hz oscillation starting about 1 second before the lockloss, and it can be seen in DARM, all QUADs, MICH, PRCL, and SRCL.

Lockloss times:

2025-02-14 07:15 UTC

2025-02-14 21:15 UTC

2025-02-16 09:48 UTC

There was another instance of a lockloss that looked just like these on February 7th 2025 at 05:47UTC as well.

Comments related to this report
oli.patane@LIGO.ORG - 18:38, Monday 17 February 2025 (82863)

Some more of these weird locklosses from the last day:

2025-02-17 12:53 UTC

2025-02-17 17:04 UTC (82856)

2025-02-18 00:06 UTC (82860)

oli.patane@LIGO.ORG - 20:22, Monday 17 February 2025 (82866)
Displaying report 1-1 of 1.