PRLC2 Gain increased

I increased the PRCL2 gain that is set in lownoise length control from 1.0 to 1.4 to increase the overall PRCL loop gain by 40%. We have been seeing locklosses with 11 Hz oscillations that are probably due to marginal stability in PRCL. I changed line 5577 of the ISC_LOCK guardian, saved, and loaded. Ibrahim will post an alog with more info and open loop gain plots.

Comments related to this report
elenna.capote@LIGO.ORG - 18:02, Wednesday 19 February 2025 (82919)

This was too high and caused a 70 Hz ring up in PRCL. I put in a gain of 1.2 now.