Reports until 13:15, Friday 21 February 2025
H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 13:15, Friday 21 February 2025 - last comment - 10:38, Monday 24 February 2025(82963)
New settings for ITMY mode 05/06

FM6 + FM8 + FM10 Gain +0.01 (+30deg phase) looks to be working for now - see attached screenshot.

 

The other settings which I tried and it didn't work are listed below,

zero phase Gain 0.01 (IY05 increasing, IY06 decreasing).

-30deg phase gain 0.01 (IY05 increasing, IY06 decreasing).

Images attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 15:26, Friday 21 February 2025 (82964)

We lost lock and then during the next lock Corey applied the above settings (in bold fonts) and it seems to be working fine. Hence, I will continue with this for the next few lock stretches. Not committing it to lscparams yet since things can still change.

rahul.kumar@LIGO.ORG - 10:38, Monday 24 February 2025 (83007)SUS

FM6 + FM8 + FM10 Gain +0.01 (+30deg phase) have been committed to lscparams for ITMY mode 05/06.