Reports until 12:16, Monday 24 February 2025
H1 PSL
oli.patane@LIGO.ORG - posted 12:16, Monday 24 February 2025 - last comment - 13:14, Monday 24 February 2025(83011)
PSL 10-Day Trends

Closes FAMIS#31074, last checked 82857

 

Six days ago on February 18th, PMC REFL OUT increased a bit but also got almost twice as loud. The mean also seemed to oscillate a bit over the past day.

Everything else is looking normal.

Images attached to this report
Comments related to this report
jason.oberling@LIGO.ORG - 13:14, Monday 24 February 2025 (83016)

We tried to tweak the PMC beam alignment last week, which coincides with the increase in PMC Refl variation.  We did not see any change in PMC Trans with the tweak, but clearly the PMC Refl signal became more noisy.  At this time I'm not sure why this happened.  We've seen in the past that the PMC alignment being off can cause the Refl signal to get very noisy, which is cured by fixing the alignment.  Not the case here, as the alignment was already good when we tried to tweak it.  I don't see anything in the other trends that would indicate a reason behind this more noisy PMC Refl.  We'll continue to monitor this.