yashasvininad.moon@LIGO.ORG - posted 09:42, Monday 24 February 2025 - last comment - 12:54, Monday 24 February 2025(83001)
DQ Shift LHO 03 Feb- 09 Feb 2025
Summary: Average duty cycle for LHO this week was 65.4%
The BNS range fluctuated between 140 and 160Mpc this week
A couple of the locklosses can be explained due to ground motion
Friday's earthquake at 04:51 UTC
Saturday's earthquake at 23:31 UTC, which extended to sunday morning
Multiple Superevents this week!
Strange noise pattern in H1 BSC2 motion Y Wednesday through Sunday
Fscan line count was very low on Saturday and Sunday (below 600)
Multiple new channels in Hveto this week

Full report: https://wiki.ligo.org/DetChar/DataQuality/DQShiftLHO20250203
Comments related to this report
camilla.compton@LIGO.ORG - 12:54, Monday 24 February 2025 (83014)DetChar, ISC, SEI

Yashasvininad interestingly pointed out some BSC2 (BS chamber) Accelerometer motion wandering at 5-10Hz that started around Feb 3rd-Feb 4th  /summary/day/20250204/pem/accelerometers_corner_bscs/ and we still have. I cannot see it before Feb. It's very visible in the last two days. e.g. plot.