Sheila, Camilla
The NLG vs OPO trans powers in 82202 didn't make sense. We thought it could be pump depletion from a high seed so we reduced Seed from 0.6 to 0.2mW. NLG measured following 76542.
125uW for NLG of 80 seemed much more sensible but when we increased the seed back to 0.6uW we got the same NLG so were not seeing pump depletion.
| OPO Trans (uW) | NLG | Seed Launch (mW) |
| 80 | 11.9 | 0.2 |
| 125 | 83.0 | 0.2 |
| 125 | 79.0 | 0.51 |
Plot attached shows the power in and refl off OPO, we are happy with the current OPO position and don;t think that the crystal has more losses yet.
Looking at the old data, NLGs measured on Thursday 09 January 2025:
Next time we take NLG data, we should make sure that the seed power is low enough that the OPO trans power is steady at the requested power, so the OPO is not experiencing pump depletion.