SQZ Work Today: Increasing SHG OPO Pump light, Homodyne Measurements, SQZ FIS and FDS Data Set.

Sheila, Camilla

After TJ found out OPO was struggling to get enough SHG pump power to lock 82196, Sheila repeated Daniel's 82057 SHG work as he had increased H1:SQZ-SHG_GR_DC_POWERMON from 95 to 125mW but now it's down to 92mW: Tried steering the beam with picos moves, and by adjusting the temperature it improved to 93mW only.

We went only SQZT0 and Sheila adjusted the alignment into the OPO pump fiber with the OPO unlocked, bringing the the OPO REFL DC power from 1.7 to 1.9mW.   We also moved the SHG wave plate further to maximize the amount of light Now CLF could lock with controlmon around 5.8V. Much better and closer to the center of the range so should avoid this mornings 82196 issues.

Homdyne Work:

To take the below data, SEED power reduced back to 0.6mW, and then:

Type NLG SQZ dB  @ 1kHz Angle DTT Ref Notes
Dark Noise N/A   N/A ref 0 This and shot noise was noisy <300Hz at times when the OPO was locking or scanning, unsure why.
ASQZ 11.2 14.2 241 ref 2 opo_grTrans_setpoint_uW = 80uW
SQZ 11.2 -6.8 154 ref 3 reduced LO loop gain from 15 to -1
SQZ 14.3 -6.1 182 ref 4
opo_grTrans_setpoint_uW = 120uW
reduced LO loop gain from -1  to -12
ASQZ 14.3 17.8 216 ref 5  
ASQZ 16.0 19.1 210 ref 6 opo_grTrans_setpoint_uW = 140uW
SQZ 16.0   191 ref 7  
SQZ 16.0 -6.8 190 ref 8 increased LO loop gain from -12 to -1 as was looking peaky
Shot Noise N/A   N/A ref 1
Blocked SEED, LO only.

We measured ~6.5dB of SQZ on the HD and up to 19dB of ASQZ. Plot attached.

Next time we work on the HD, we should measure the LO loop to know the correct gain to use.

SQZ data set

UTC Type CLF Phase DTT ref
19:02:00 - 19:08:00 No SQZ N/A ref 0
19:14:00 - 19:20:00 (6mins) FDS SQZ 177deg ref 1
19:21:00 - 19:25:00 (4mins) FDS Mid + SQZ 215deg ref 2
19:26:00 - 19:30:00 (4mins) FDS Mid - SQZ 125deg ref 3
19:32:00 - 19:36:00 (4mins) FDS ASQZ (-sign) 108deg ref 4
19:40:00- 19:43:00 (3mins) FIS ASQZ (-sign) 108deg ref 5
19:43:15- 19:45:15 (2mins) FIS ASQZ +10deg (-sign) 118deg ref 6
19:45:30- 19:47:30 (2mins)
FIS ASQZ -10deg
(-sign) 98deg
ref 7
19:48:00 - 19:51:00 (3mins)
FIS SQZ
177deg
ref 8
19:51:30 - 19:54:30 (3mins)
FIS Mid + SQZ
(check, small low freq glitch at 19:53:49)
215deg
ref 9
19:55:00 - 19:58:00 (3mins)
FIS Mid - SQZ
125deg
ref 10
Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 09:05, Tuesday 25 February 2025 (83031)

In 83022  we found that we had pump depletion during these measurements so that the OPO trs powers were actually lower than reported

sheila.dwyer@LIGO.ORG - 13:51, Tuesday 25 February 2025 (83034)

I've imported Camilla's data from dtt, subtracted the dark noise.  As Camilla notes above, the NLG measurements here don't nicely fit a model for a consistent threshold power.  Instead of using the NLG data, I've allowed the threshold power to be one of the parameters that varies in the fit, along with total efficiency and phase noise.  In principle one could also use this data to estimate the technical nosie that limits squeezing, but I haven't tried that with just a few points here.

The attached shows the NLG measurements vs what we would expect given the threshold power that the squeezing and anti-squeezing fits suggest.  This model suggests that the total efficiency to of the homodyne squeezing is only only 81%, which seems too low. 