camilla.compton@LIGO.ORG - posted 10:36, Wednesday 26 February 2025 (83032)
Discarded SQZ Homodyne vs NLG Measurements

Sheila, Matt, Camilla

We repeated the HD data set taken in 82202 as in 83022 we found we had pump depletion during these measurements so that the OPO trans powers were actually lower than reported. We had some issues at first which ended up being that with HAM7 ISI tripped the optics were moving around too much, plot of optics here. After we fixed that, we retook the data, so that our real data set is in 83039. Below documents the steps taken and initial data that we ended up not trusting. 

Then started data taking:

Sheila and Matt measured the LO OLG as 2.5kHz 80deg phase margin is LO loop with gain -12 LO on LOCKED_HD with opo_grTrans_setpoint_uW = 80uW before we started.

One we got to the 110uW measurements, we felt the squeezing was unstable, moving independently of the SQZ angle, steps taken to help this:

Data saved to camilla.compton/Documents/sqz/templates/dtt/20250225_HD.xml

FC2 is misaligned during this dataset.

Type NLG SQZ dB  @ 1kHz Angle DTT Ref Notes
Dark Noise N/A   N/A ref 0 This and shot noise was noisy <300Hz at times when the OPO was locking or scanning, unsure why.
Shot Noise N/A   N/A ref 10
Blocked SEED, LO only.
SQZ 12 -7.1 157 ref1
opo_grTrans_setpoint_uW = 80uW
Amplified Max = 0.0107mW
Amplified Min = 0.00037mW
UnAmp = 0.00095
Dark = 6.5e-5
NLG = 11.9(max/min) and12.0 (usual method)
ASQZ 12 14.7 243 ref2
Mean SQZ 12 11.8 N/A ref3
SQZ 66 -6.6 167 ref4
opo_grTrans_setpoint_uW = 120uW
Amplified Max = 0.05347mW
Amplified Min = 0.0002933mW
UnAmp = 0.00095
Dark = 6.5e-5
NLG = 66 (max/min) and 60.3 (usual method)
ASQZ 66 22.6 229 ref5
Mean SQZ 66 19.7 N/A ref6
SQZ 23 -7.0 156 ref7
opo_grTrans_setpoint_uW = 100uW
Amplified Max = 0.0210425mW
Amplified Min = 0.00034922mW
NLG = 23.0 (max/min) and 23.7 (usual method)
ASQZ 23 18.1 236 ref8
Mean SQZ 23 15 N/A ref9
SQZ 36 -7.2 165 ref11
opo_grTrans_setpoint_uW = 110uW.
Amplified Max = 0.033029mW
Amplified Min = 0.00033752mW
NLG = 36.0 (max/min) and  37.2 (usual method)

OPO gain reduced -8 to -14. HAM7 WD untripped. Visibility again measured.
ASQZ 36 19.9 230 ref12 Rechecked after visibility adjusted, no change
Mean SQZ 36 16.9 N/A ref13  
SQZ 36 -7.2 165 ref14 Remeasured after visibility again measured.
Images attached to this report