Displaying report 1-1 of 1.
Reports until 17:52, Tuesday 25 February 2025
H1 SEI (SEI)
edgard.bonilla@LIGO.ORG - posted 17:52, Tuesday 25 February 2025 (83052)
Picket fence updated to restore missing pickets.

original post: SEI 2513

I restored the MSO (Missoula, Montana) picket to the picket fence. Hopefully it will increase the reliability of the picket fence for the few earthquakes that come from the northeast.

Turns out they changed the sensor to a different data rate and it hadn't been mentioned in the data aggregator.

Please SVN up at the picket fence folder if you would like to get this change.