Wed Feb 26 10:16:27 2025 INFO: Fill completed in 16min 24secs
This is the second run of new rate-of-change code. I have created a new set of MEDMs and a new Plot format to show the rate-of-change channels and the new trip level.
MEDM:
The main medm shows the six rate-of-change channels as bar charts (TC-A = blue, TC-B = purple). The trip level (60degc) is shown as a grey bar, the first ROC channel to exceed this stops the fill.
The related trend MEDM has been extended to show the six ROC channels, keeping with the same color scheme.
PLOT:
The plot has an additional panel showing the six ROC channels. The trip level is shown as a horizontal line. Both panels show start/stop times as vertical lines.