Displaying report 1-1 of 1.
Reports until 13:52, Wednesday 26 February 2025
H1 ISC
thomas.shaffer@LIGO.ORG - posted 13:52, Wednesday 26 February 2025 - last comment - 14:07, Wednesday 26 February 2025(83067)
Ran A2L script and PRCLFF tuned

Based on Oli's range checks (alog83063) we decided to run the a2l script and a PRCLFF measurement after getting run coordinator approval. Below are the results of the a2l script, a few moving quite a bit. These have been added into lscparams.py and they are not in SDF. Jenne will post the PRCLFF results.

RESULTS

    Initial Final Diff
ETMX P 3.34 3.23 -0.11
  Y 4.9 4.91 0.01
ETMY P 5.56 5.49 -0.07
  Y 1.28 1.35 0.07
ITMX P -0.66 -0.53 0.13
  Y 2.97 3.21 0.24
ITMY P -0.06 0.06 0.12
  Y -2.51 -2.74 -0.23
Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 14:07, Wednesday 26 February 2025 (83069)

We reran the PRCLFF injection template to try and improve the range in the 20-50 Hz range. The template was at /opt/rtcds/userapps/release/lsc/h1/scripts/feedforward/PRCL_excitation_gain_adjust.xml.

The right two panels are the magnitude and phase of the PRCL to DARM transfer function.

We tried gains of 0.9 (starting value)

1.0

1.3

1.5

We found the TF was minimised in the 20-50Hz range using a gain of 1.3 in PRCLFF (pink trace).

The live trace was our last step (red) which was a gain of 1.5.

The coherences are shown in the bottom left corner (labels correct but colours don't correlate with the TF colours).

(NB: Ref 1 darm spectra in top left is old reference - ignore).

TJ added the value to lsc params and I accepted it in the OBSERVE snap file.

 

Images attached to this comment
Displaying report 1-1 of 1.