Reports until 16:02, Wednesday 26 February 2025
H1 General (OpsInfo)
oli.patane@LIGO.ORG - posted 16:02, Wednesday 26 February 2025 (83068)
Looking at weird DRMI noise

This weird noise was first noticed in 82997 during OFFLOAD_DRMI_ASC. The first instance of this happening while relocking was three days ago 2025-02-23 03:59:19 UTC. It started showing up LSC-PR_GAIN and LSC-POPAIR_B_RF90_I_NORM and the lower stages of SR2 and SRM. Almost every relock since then has seen these glitches. They almost always start showing up in OFFLOAD_DRMI_ASC, but I've found a few instances(one, two, three) where the noise clearly starts during DRMI_LOCKED_CHECK_ASC, the state before OFFLOAD_DRMI_ASC. Next time we lose lock we will be sitting in DRMI_LOCKED_CHECK_ASC, so we will probably see this ringup then.

Images attached to this report