TITLE: 02/27 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: TJ
SHIFT SUMMARY: 1 lockloss and we're on our way back past the troublesome CHECK_ASC now. I had to reduce the gain of SRC2_p from 60 to 40. We're about to start powering up now.
LOG: No log.
- 01:02 UTC superevent S250227y
- 02:44 UTC lockloss
- I03:28 UTC Held at CHECK_ASC and it started ringing up after a few minutes and we lost lock ~30 seconds later
- 03:37 UTC Held again and reduced the gain to 40, we could survive as it rung up and down. I ran a few averages of the OLG
- I put in the wrong gain and we lost lock
- ALS keeps dropping out during DRMI
- 05:00 UTC, we're struggling to get DRMI, keep going through PRMI
- 05:17 UTC after doing PRMI 3 times in a row I dropped to do another IA
- 05:48 I reduced the gain to 40 and kept going and we seems fine?