Displaying report 1-1 of 1.
Reports until 14:41, Thursday 27 February 2025
H1 ISC (OpsInfo)
thomas.shaffer@LIGO.ORG - posted 14:41, Thursday 27 February 2025 (83092)
SRC2 P gain brought down to 40

We've been having some issues with SRC2 P starting to go unstable after engaging for DRMI (alog83080, alog82997). Ryan C tested out lower the gain from 60 -> 40 on Sheila's suggestion yesterday and it seemed to work (alog83078), and I also bashed it in during a relock today that started to go unstable. Since this seems to work and the gain is brought back to 60 later in ENGAGE_ASC_FOR_FULL_IFO, we've made the change in ISC_DRMI and loaded the guardian.

Displaying report 1-1 of 1.