Reports until 16:44, Tuesday 04 March 2025
H1 CDS
jonathan.hanks@LIGO.ORG - posted 16:44, Tuesday 04 March 2025 (83175)
WP12358 digital video server work, installed h1digivideo5 and h1digivideo6, migrated cameras off of old servers
Jonathan, Erik, Dave, Patrick

As part of WP12358 we installed two new digivideo server h1digivideo5 and h1digivideo6.  These were racked in the aux rack.  To make room we removed two old conlog servers.  Both servers were installed with Debian 12 and are under puppet configuration and running the 0.1.16 version of the pylon-camera-server software.  They are connected to the new video1 switch.

We migrated cameras off of h1digivideo0, h1digivideo1, and h1digivideo3.  These machines have been powered off.

h1digivideo4 is running the following cameras

H1-VID-CAM-ALS-X
H1-VID-CAM-ALS-Y
H1-VID-CAM-FC-REFL
H1-VID-CAM-MC-REFL
H1-VID-CAM-MC-TRANS
H1-VID-CAM-MC1
H1-VID-CAM-MC2
H1-VID-CAM-MC3
H1-VID-CAM-PR2
H1-VID-CAM-PR3
H1-VID-CAM-PRM
H1-VID-CAM-ISCT6-AS-AIR
H1-VID-CAM-SRM
H1-VID-CAM-SQZT7-OPO-GR-TRANS
H1-VID-CAM-SQZT7-IR-TRANS

h1digivideo5 is running the following cameras

H1-VID-CAM-ETMX
H1-VID-CAM-ETMY
H1-VID-CAM-FC1
H1-VID-CAM-FC2
H1-VID-CAM-FCES-GREEN
H1-VID-CAM-FCES-IR-TRANS-B
H1-VID-CAM-SHG-TRANS
H1-VID-CAM15

We did a daqd restart to remove monitoring information regarding h1digivideo3 and to reflect changes in EPICS variables due to migrating from older versions of the camera software.

We still need to migrate cameras off of h1digivideo2.  That will likely happen next Tuesday.