After a lockloss while attempting to relock this morning, I ran the dark offset script (/opt/rtcds/userapps/release/isc/h1/scripts/dark_offsets/dark_offsets_exe.py) after taking the IMC offline and shuttering ALS with the hope of fixing some of our ASC troubles.
I've attached a text file of the script output showing what all was changed, as well as screenshots of these being accepted in SDF safe.snap tables (TJ has more that he will add in a comment). These will likely need further accepting once we eventually reach NLN.