Monthly FAMIS Check (#26499)
T240 Centering Script Output:
Averaging Mass Centering channels for 10 [sec] ...
2025-03-07 11:28:08.262570
There are 15 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.975 [V]
ETMX T240 2 DOF Y/V = -1.02 [V]
ETMX T240 2 DOF Z/W = -0.554 [V]
ITMX T240 1 DOF X/U = -1.776 [V]
ITMX T240 1 DOF Y/V = 0.392 [V]
ITMX T240 1 DOF Z/W = 0.484 [V]
ITMX T240 3 DOF X/U = -1.843 [V]
ITMY T240 3 DOF X/U = -0.789 [V]
ITMY T240 3 DOF Z/W = -2.313 [V]
BS T240 1 DOF Y/V = -0.351 [V]
BS T240 3 DOF Y/V = -0.311 [V]
BS T240 3 DOF Z/W = -0.432 [V]
HAM8 1 DOF X/U = -0.317 [V]
HAM8 1 DOF Y/V = -0.434 [V]
HAM8 1 DOF Z/W = -0.712 [V]
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.006 [V]
ETMX T240 1 DOF Y/V = -0.014 [V]
ETMX T240 1 DOF Z/W = 0.009 [V]
ETMX T240 3 DOF X/U = 0.029 [V]
ETMX T240 3 DOF Y/V = -0.068 [V]
ETMX T240 3 DOF Z/W = -0.005 [V]
ETMY T240 1 DOF X/U = 0.082 [V]
ETMY T240 1 DOF Y/V = 0.171 [V]
ETMY T240 1 DOF Z/W = 0.24 [V]
ETMY T240 2 DOF X/U = -0.067 [V]
ETMY T240 2 DOF Y/V = 0.216 [V]
ETMY T240 2 DOF Z/W = 0.073 [V]
ETMY T240 3 DOF X/U = 0.26 [V]
ETMY T240 3 DOF Y/V = 0.114 [V]
ETMY T240 3 DOF Z/W = 0.146 [V]
ITMX T240 2 DOF X/U = 0.181 [V]
ITMX T240 2 DOF Y/V = 0.294 [V]
ITMX T240 2 DOF Z/W = 0.245 [V]
ITMX T240 3 DOF Y/V = 0.13 [V]
ITMX T240 3 DOF Z/W = 0.133 [V]
ITMY T240 1 DOF X/U = 0.082 [V]
ITMY T240 1 DOF Y/V = 0.123 [V]
ITMY T240 1 DOF Z/W = 0.04 [V]
ITMY T240 2 DOF X/U = 0.04 [V]
ITMY T240 2 DOF Y/V = 0.263 [V]
ITMY T240 2 DOF Z/W = 0.132 [V]
ITMY T240 3 DOF Y/V = 0.08 [V]
BS T240 1 DOF X/U = -0.161 [V]
BS T240 1 DOF Z/W = 0.156 [V]
BS T240 2 DOF X/U = -0.031 [V]
BS T240 2 DOF Y/V = 0.072 [V]
BS T240 2 DOF Z/W = -0.092 [V]
BS T240 3 DOF X/U = -0.139 [V]
Assessment complete.
STS Centering Script Output:
Averaging Mass Centering channels for 10 [sec] ...
2025-03-07 11:37:12.263138
There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -2.334 [V]
All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.503 [V]
STS A DOF Y/V = -0.757 [V]
STS A DOF Z/W = -0.603 [V]
STS B DOF X/U = 0.235 [V]
STS B DOF Y/V = 0.954 [V]
STS B DOF Z/W = -0.319 [V]
STS C DOF X/U = -0.862 [V]
STS C DOF Y/V = 0.801 [V]
STS C DOF Z/W = 0.681 [V]
STS EX DOF X/U = -0.041 [V]
STS EX DOF Y/V = -0.05 [V]
STS EX DOF Z/W = 0.102 [V]
STS EY DOF Y/V = -0.065 [V]
STS EY DOF Z/W = 1.318 [V]
STS FC DOF X/U = 0.195 [V]
STS FC DOF Y/V = -1.104 [V]
STS FC DOF Z/W = 0.659 [V]
Assessment complete.