Displaying report 1-1 of 1.
Reports until 19:16, Wednesday 30 October 2013
H1 CDS
patrick.thomas@LIGO.ORG - posted 19:16, Wednesday 30 October 2013 (8324)
Restarted Conlog after setting paths for caRepeater
I noticed that Conlog was not reconnecting to some PEM channels after their IOCs were restarted.

One hypothesis is that it may need to have the caRepeater running, which it has not been.

I stopped Conlog around 18:12. I set the environment variable $PATH to include the path to the caRepeater binary. I restarted Conlog. I got an error not finding a library needed by caRepeater. I stopped Conlog and set the environment variable $LD_LIBRARY_PATH to include the path to the library. I restarted Conlog and it ran without any further errors. These environment variables are set in /home/controls/bashrc_import which is sourced by /home/controls/.bashrc on h1conlog.

It remains to be seen if this fixes the problem.