Sheila, Oli
Vlad had mentioned in the last commissioning meeting that our bandpass filters for our PIs were too wide, so I looked and sure enough, they are way too wide (up to 6 Hz wide!) and contained part/most of other peaks.
Since PI24 and PI31 are the two that we care about the most right now, I went in and narrowed them as well as shifted the band location to actually be centered on those modes (h1susprocpi diffs, accepted 83421).
I'll be taking a look at PI28 and PI29's bandpasses and adjusting those to what makes sense.
Table below shows before and after locations of the band passes (the values are after the downconversion, which is why they are in the 400 Hz range instead of the 10.4 kHz range)(the before/after links show the bandpasses on the bottom plot using vertical lines)
Mode | Peak Location | Before | Now |
PI 24 | 431.75 | 428.5 - 433.5 | 430.75 - 432.75 |
PI 31 | 428.625 | 425 - 431 | 427.125 - 430.125 |