A2L Script Multi Pretty output

Dropped from Observing to Commissioning at 17:22:53 UTC

TJ and I ran the A2L Script Multi Pretty script on All Quads.

Python3 /opt/rtcds/userapps/release/isc/h1/scripts/a2l/a2l_min_multi_pretty.py -a

['ETMX', 'ETMY', 'ITMX', 'ITMY'] ['P', 'Y'] a2l script done!
All complete.

*************************************************
RESULTS

| OPTIC|P/Y| Initial | Final |  Diff |
| ETMX | P |   3.23  |  3.31 |  0.08 |
| ETMX | Y |    4.9  |  4.96 |  0.06 |
| ETMY | P |   5.52  |  5.57 |  0.05 |
| ETMY | Y |   1.35  |  1.37 |  0.02 |
| ITMX | P |  -0.53  | -0.54 | -0.01 |
| ITMX | Y |   3.21  |  3.23 |  0.02 |
| ITMY | P |   0.06  |  0.04 | -0.02 |
| ITMY | Y |  -2.74  | -2.76 | -0.02 |

While also watching this ndscope to ensure that they crossed 0 using this ndscope templat: 
ndscope /opt/rtcds/userapps/release/asc/h1/templates/ndscope/A2L_script_ADS.yaml

Returned to Observing at 17:47:22 UTC

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 11:08, Wednesday 19 March 2025 (83455)

I've now merged a2l_min_multi_pretty.py and a2l_min_multi.py so that the terminal output looks a bit better and it now has the option to print out that table in html format for easy alogging.