Reports until 14:25, Tuesday 25 March 2025
H1 SUS
marc.pirello@LIGO.ORG - posted 14:25, Tuesday 25 March 2025 - last comment - 11:53, Friday 28 March 2025(83554)
SUS-C4 Power Supply Chirping

The Kepco Power Supply for SUS-C4 started chirping at the end of maintenance today.  By 2pm the chirping is more regular.  The draw on the supply is 7A, typical failing fans last a few days once they get to this stage.  We should replace this one before the weekend, as a target of opportunity.  Down time will be 30 mins start to finish.

WP12406

M. Pirello, F. Clara

Comments related to this report
marc.pirello@LIGO.ORG - 11:53, Friday 28 March 2025 (83617)

Due to earthquake we took a window of opportunity to replace the SUS-C4 Kepco Power Supply which controls HAM1 and HAM2 suspensions.  These suspensions were placed into safe and the supply replaced.  We replaced only the -18V supply, the +18V matching supply was replaced in December 2022 so we left it in place.

WP12406

M. Pirello, F. Clara