Displaying report 1-1 of 1.
Reports until 13:42, Wednesday 26 March 2025
H1 SQZ
camilla.compton@LIGO.ORG - posted 13:42, Wednesday 26 March 2025 - last comment - 15:58, Monday 31 March 2025(83570)
SQZ Data set with high NLG, then adjusted SRCL offset and FC detuning.

Sheila, Camilla

Reduced HAM7 rejected pump power and increased SHG launch, turned OPO trans setpoint up to 120uW and measured NLG with 76542 to be 58 (this was a little lower than with 120uW in 83370). OPO gain turned down from -8  to -12. ADF was on for all apart from "Mean SQZ w/o ADF".

Type Time (UTC) Angle DTT Ref
No SQZ 16:01:00 - 16:15:00 N/A ref 0
SQZ 16:56:30 - 16:59:30 (CLF-) 174 ref1
SQZ +10deg 17:00:00 - 17:03:00 (CLF-) 184 ref2
SQZ -10deg 17:03:30 - 17:06:30 (CLF-) 164 ref3
Mean SQZ w/o ADF 17:07:30 - 17:10:30 N/A ref4
Mean SQZ w/ ADF 17:11:00 - 17:14:00 N/A ref5
Mid SQZ + 17:17:00 - 17:20:00 (CLF-) 209 ref6
Mid SQZ - 17:21:30 - 17:24:30 (CLF-) 152 ref7
ASQZ 17:27:30 - 17:30:30 (CLF-) 80 ref8
ASQZ +10deg 17:31:30 - 17:34:30 (CLF-) 90 ref9
ASQZ -10deg 17:35:00 -17:38:00 (CLF-) 70 ref10
Then went to FDS      
FDS SQZ, SRCL -191 17:46:00 - 17:49:00 (CLF-) 174 ref11
FDS SQZ +10deg, SRCL -191 17:49:30 - 17:51:30 (2mins) (CLF-) 184 ref12
FDS SQZ -10deg, SRCL -191 17:52:00 -17:54:00 (2mins) (CLF-) 164 ref13
FDS SQZ, SRCL -290 17:56:30 - 17:59:30 (CLF-) 146 ref14
FDS SQZ +10deg, SRCL -290 18:00:00 - 18:02:00 (2mins) (CLF-) 156 ref15
FDS SQZ -10deg, SRCL -290 18:02:30 - 18:04:30 (2mins) (CLF-) 136 ref16
Starting FC detuning -36Hz      
FDS SQZ, SRCL -290, FC detuning -40Hz 18:08:30 - 18:11:30 (CLF-) 146 ref17
FDS SQZ, SRCL -290, FC detuning -32Hz 18:12:00 - 18:15:00 (CLF-) 146 ref18
FDS SQZ, SRCL -290, FC detuning -32Hz 18:18:00 - 18:21:00 (CLF-) 149 ref19
FDS SQZ, SRCL -290, FC detuning -28Hz* 18:21:30 - 18:24:30 (CLF-) 149 ref20
FDS SQZ, SRCL -290, FC detuning -24Hz 18:225:30 - 18:28:30 (CLF-) 149 ref21
OPO trans back to nominal 80uW, NLG 12      
FDS SQZ, SRCL -290, FC detuning -28Hz 18:46:30 - 18:49:00 (2m30) (CLF-) 170 ref22
FDS SQZ, SRCL -191, FC detuning -36Hz 19:03:30 - 19:06:00 (2m30) (CLF-) 171 ref23

* For NLG of 58, SRCL -290, FC detuning -28Hz looked best.

Plots attached of FIS data showing SQZ, Mean SQZ, Mid SQZ and also SQZ and ASQZ, filename shown on screenshot.

Also did FDS SQZ, +/-10deg with nominal SRCL detuning (-191) and -290, plot attached. And adjusted the FC de-tuning with SRCL offset at -290, plot attached.

Finally we went back to the nominal NLG (NLG of 12 with 80uW OPO Trans setpoint) and checked FDS SQZ with the best found settings at high NLG: SRCL -290, FC de-tuning -28Hz and back to nominal settings, DARM plot attached.  We didn't have time to fully tune the angle in both settings so could repeat this to check at which settings the range is best. Sheila ran a SQZ angle scan at these settings (SRCL -290, FC de-tuning -28Hz), see attached, it is less frequency dependent than than the scans taken the day before at SRCL -191 (nominal) and -190, FC de-tuning -36Hz (nominal), plot attached.

opo_grTrans_ setpoint_uW Amplified Max Amplified Min UnAmp Dark NLG (usual) NLG (maxmin) OPO Gain
120 0.0540944 0.00026378 0.000913452 -0.0000233 57.75 58.68 -12
80 0.010857 0.0002927 0.000904305 -0.0000219 11.72 12.57 -8
Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 14:46, Wednesday 26 March 2025 (83572)

Here are some plots of Camilla's first dataset above, changing the SRC detuning while adjsuting the squeezing angle for high frequency squeezing, made with the same code used for 80318, which is available here

For the gwinc model, I've set the generated squeezing to 23 dB based on Camilla's measured NLG of 58.  Based on the loss estimates from 83457, I've set the Injection loss to 0.178 (17.8% loss) and the PD efficiency (readout efficiency) to 0.815, and the phase noise to 0.

The third attachment shows the model where I've manually adjusted the SRC detuning to roughly match the subtracted squeezing, and the second shows a linear fit of SRCL offset to these detunings.  This suggests that the SRCL offset should be at -306 counts to reduce the SRCL offset, and that we are currently running with a SRCL detuning of 0.013 radians. 

 

 

Images attached to this comment
camilla.compton@LIGO.ORG - 10:51, Thursday 27 March 2025 (83585)

This morning we put SRCL offset to -306, FC de-tuning -28Hz. I then ran SCAN_SQZANG which changed the angle form 171 to 161 and compare the before and after DARM, attached, SQZ looks alot better at higher frequencies, however the range, attached, is similar or a little worse, maybe the 300Hz (yellow BLRMs) squeezing is slightly worse.

Updated DTT legend as had typo.

Images attached to this comment
sheila.dwyer@LIGO.ORG - 15:58, Monday 31 March 2025 (83666)

Here are some preliminary plots from Camilla's data set of different squeezing angles taken at an NLG of 58 with the SRCL offset at it's nominal -191 counts setting, which we believe is about 13 mrad SRC detuning. 

The first plot shows some assumptions that go into making this model, we start with an assumption about arm power, use the noise budget estimate of non quantum noise at 2kHz (which may be out of date now), and set the readout losses to fit the no squeezing data at 2.1-2.3kHz.  Then subtract this quantum noise model without squeezing  from the no squeezing data, and use that as an estimate of the non-quantum noise, which can be added to all of the quantum noise models for different squeezing angles to compare to the measurement. (second plot is a somewhat overwhelming plot of all this added for completeness).

I've set the phase noise to 0 based on 83457.  Using the level of sqz and anti-squeeze at 2.1-2.3 kHz, we infer that the NLG was 63 and the total efficency was 66.5%.  Camilla measured the NLG to be 58, for 120uW circulating power, but in 83370 she measured 61-63 for 120uW.   The third plot here shows the data that Camilla took with the LO loop unlocked, so that the squeezing angle is averaging and rotating freely.  Using this and knowledge of the NLG, we should be able to infer the total squeezing efficiency as a function of frequency. Doing the subtraction of non quantum noise increases the infered efficiency, (compare thick lines to thin), the two different values of NLG suggest rather different efficiencies. There is evidence that the efficiency frequency dependent, which could be caused by a number of effects. Below 200 Hz there is some excess noise in the mean sqz trace, as you can see here, which causes the efficiency infered to be above 1.

The next two plots show the model broken into more readable plots, with the only thing I've adjusted by hand being the SRC detuning.  There is a discrepancy between the model + noise for the anti-squeezing and anti-squeezing +/-10 degrees traces without the filter cavity, which seems like it could be some excess noise that is similar for the different traces.  This is similar to the discrepancy seen in the last plot in 82097, but it is larger in this higher NLG dataset.

 

 

Images attached to this comment
Displaying report 1-1 of 1.