Displaying report 1-1 of 1.
Reports until 12:07, Thursday 27 March 2025
H1 SQZ
camilla.compton@LIGO.ORG - posted 12:07, Thursday 27 March 2025 (83589)
Bad SQZ Data Set with SRCL offset at -306

Sheila, Camilla

This morning we changed SRCL offset from -191 to -306 and FC detuning from -34 to -28, as discussed in  83570. Decided to take a  SQZ dataset here.

Increased SHG launch, turned OPO trans setpoint up from 80uW to 95uW to increase NLG from 11 to 19 (as we had earlier in O4). Measured NLG with 76542. OPO gain left at -8.

Had some strange HAM7 CPS glitches and WD trips. Think we manged to avoid these effecting the data.

Forgot to turn of SQZ ASC, realized and then we lost lock, this data is not good as the AS42 and ZM alignment offsets were moving around a lot.

opo_grTrans_ setpoint_uW Amplified Max Amplified Min UnAmp Dark NLG (usual) NLG (maxmin) OPO Gain
95  0.0179401 0.000271566 -0.00002333 0.000906905 19.3 20.8 -8

 

Type Time (UTC) SQZ @1kHz (dB) Angle DTT Ref
No SQZ 18:11:30 - 18:20:00 N/A N/A ref 0
MeanSQZ w/o ADF 18:22:30 - 18:25:30 13.3 N/A ref1
FIS Mid SQZ + 18:28:30 - 18:31:30   (CLF-) 195 ref2
FIS Mid SQZ - 18:38:30 - 18:41:30   (CLF-) 127 ref3
FIS ASQZ 18:44:00 - 18:47:00 15.8 (CLF-) 68 ref4
FIS ASQZ +10deg 18:47:30 - 18:50:30 15.2 (CLF-) 78 ref5
FIS ASQZ -10deg 18:51:00 - 18:54:00 15.2 (CLF-) 58 ref6
Images attached to this report