SQZ back to nominal

After this morning's SRCL offset change and SQZ NLG change 83589, I returned FC de-tuning to -34Hz, SQZ angle to 171, and OPO trans setpoint to 80uW. Adjusted OPO temp and measured NLG to be 12 following 76542

opo_grTrans_ setpoint_uW Amplified Max Amplified Min UnAmp Dark NLG (usual) NLG (maxmin) OPO Gain
80 0.0110211 0.0002941 -0.000023 0.0009199 11.7 12.7 -8