Displaying report 1-1 of 1.
Reports until 08:46, Monday 31 March 2025
H1 ISC
sheila.dwyer@LIGO.ORG - posted 08:46, Monday 31 March 2025 (83655)
POP 18 gains restored to their previous normal gain of 2

Last week Corey changed the gains of POP18 because of difficulties locking DRMI.  83540  To avoid having the histories of these POP18 build ups being confusing, I've moved the gain of 2 into the trigger matrix, and in sdf set the locking gains back to 2.  (These gains were changed from 1 to 2 when the 50/50 splitter was added to the POP path.) 

I've edited line 238 in ISC_DRMI to set the trigger matrix element to 2.

Images attached to this report