H1 SEI
camilla.compton@LIGO.ORG - posted 15:22, Wednesday 02 April 2025 - last comment - 16:14, Wednesday 02 April 2025(83705)
Looking at SEI HEPI/ISI Pointing after Locking

Ibrahim, Ryan S, Betsy, Sheila, Camilla

Getting a baseline for how much the HAM chambers have moved since they were locked.

Highlighted the highest changes but none of these look particularly large.

HAM5 and HAM6 tripped just at the end of these trends too, not included in differences above, maybe a WD trip when a SEI is locked doesn't matter anyway.

Images attached to this report
Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 16:14, Wednesday 02 April 2025 (83708)SEI

Same comparisons are below for HAM1, HAM2, HAM3 for before and after HEPI Locking

HAM1:

L4Cs: Just got noiser since Jim moved them. I don't think this can be used as a comparison for alignment but screenshotted below nonetheless.

HEPI: Largest change is in Z with 11.2um

HAM1 plots also show another change about 4/5 hours ago, which is the HAM1 vent

HAM2:

ISI: Largest change is in RZ with 22.3urad

HEPI: Largest change is in HP by 10.9um

HAM3:

ISI: Largest change is in RZ with 23.4urad

HEPI: Largest changes are Y  by 10.3um and VP by 13.8um

Images attached to this comment