Reports until 12:14, Friday 25 April 2025
H1 PSL (PSL)
ibrahim.abouelfettouh@LIGO.ORG - posted 12:14, Friday 25 April 2025 (83720)
PSL Weekly Report - Weekly FAMIS 26397

Closes FAMIS 26397, last checked in alog 84018

Laser Status:
    NPRO output power is 1.841W
    AMP1 output power is 70.43W
    AMP2 output power is 140.4W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 2 days, 23 hr 11 minutes
    Reflected power = 23.28W
    Transmitted power = 105.5W
    PowerSum = 128.8W

FSS:
    It has been locked for 1 days 20 hr and 35 min
    TPD[V] = 0.8003V

ISS:
    The diffracted power is around 3.7%
    Last saturation event was 1 days 20 hours and 35 minutes ago


Possible Issues:
    PMC reflected power is high

Displaying report 1-1 of 1.