Reports until 12:49, Thursday 03 April 2025
H1 SEI (SEI)
ibrahim.abouelfettouh@LIGO.ORG - posted 12:49, Thursday 03 April 2025 (83727)
SEI Seismometer Mass Position Check - Monthly FAMIS 26500

Closes FAMIS 26500. Last checked in alog 83228

It is worth noting that while all ISIs were in ISI_DAMPED_HEPI_OFFLINE and I did this task during lunch with minimal LVEA activity and untripped WDs, we are in a vent so values may not be nominal. Despite this, the outputs are still comparable to last month's with the same +-1 number of out-of-range STSs/T240s.

STS Centering

Averaging Mass Centering channels for 10 [sec] ...
2025-04-03 12:42:01.264160
There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -2.34 [V]
All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.623 [V]
STS A DOF Y/V = -0.678 [V]
STS A DOF Z/W = -0.626 [V]
STS B DOF X/U = 0.241 [V]
STS B DOF Y/V = 0.946 [V]
STS B DOF Z/W = -0.394 [V]
STS C DOF X/U = -0.801 [V]
STS C DOF Y/V = 0.799 [V]
STS C DOF Z/W = 0.612 [V]
STS EX DOF X/U = -0.052 [V]
STS EX DOF Y/V = -0.052 [V]
STS EX DOF Z/W = 0.067 [V]
STS EY DOF Y/V = -0.077 [V]
STS EY DOF Z/W = 1.291 [V]
STS FC DOF X/U = 0.19 [V]
STS FC DOF Y/V = -1.11 [V]
STS FC DOF Z/W = 0.653 [V]
Assessment complete.

T240 Centering

Averaging Mass Centering channels for 10 [sec] ...
2025-04-03 12:44:13.270291
There are 14 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -1.086 [V]
ETMX T240 2 DOF Y/V = -1.059 [V]
ETMX T240 2 DOF Z/W = -0.718 [V]
ITMX T240 1 DOF X/U = -1.658 [V]
ITMX T240 1 DOF Y/V = 0.416 [V]
ITMX T240 2 DOF Z/W = 0.411 [V]
ITMX T240 3 DOF X/U = -2.126 [V]
ITMY T240 3 DOF X/U = -0.835 [V]
ITMY T240 3 DOF Z/W = -2.379 [V]
BS T240 3 DOF X/U = -0.504 [V]
BS T240 3 DOF Z/W = -0.355 [V]
HAM8 1 DOF X/U = -0.316 [V]
HAM8 1 DOF Y/V = -0.438 [V]
HAM8 1 DOF Z/W = -0.723 [V]
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.079 [V]
ETMX T240 1 DOF Y/V = -0.051 [V]
ETMX T240 1 DOF Z/W = -0.05 [V]
ETMX T240 3 DOF X/U = -0.021 [V]
ETMX T240 3 DOF Y/V = -0.154 [V]
ETMX T240 3 DOF Z/W = -0.047 [V]
ETMY T240 1 DOF X/U = 0.052 [V]
ETMY T240 1 DOF Y/V = 0.13 [V]
ETMY T240 1 DOF Z/W = 0.194 [V]
ETMY T240 2 DOF X/U = -0.098 [V]
ETMY T240 2 DOF Y/V = 0.183 [V]
ETMY T240 2 DOF Z/W = 0.062 [V]
ETMY T240 3 DOF X/U = 0.21 [V]
ETMY T240 3 DOF Y/V = 0.079 [V]
ETMY T240 3 DOF Z/W = 0.105 [V]
ITMX T240 1 DOF Z/W = 0.258 [V]
ITMX T240 2 DOF X/U = 0.204 [V]
ITMX T240 2 DOF Y/V = 0.07 [V]
ITMX T240 3 DOF Y/V = 0.293 [V]
ITMX T240 3 DOF Z/W = 0.16 [V]
ITMY T240 1 DOF X/U = 0.043 [V]
ITMY T240 1 DOF Y/V = 0.088 [V]
ITMY T240 1 DOF Z/W = 0.027 [V]
ITMY T240 2 DOF X/U = 0.021 [V]
ITMY T240 2 DOF Y/V = 0.264 [V]
ITMY T240 2 DOF Z/W = 0.087 [V]
ITMY T240 3 DOF Y/V = 0.046 [V]
BS T240 1 DOF X/U = 0.107 [V]
BS T240 1 DOF Y/V = -0.274 [V]
BS T240 1 DOF Z/W = -0.208 [V]
BS T240 2 DOF X/U = 0.046 [V]
BS T240 2 DOF Y/V = -0.294 [V]
BS T240 2 DOF Z/W = 0.174 [V]
BS T240 3 DOF Y/V = -0.044 [V]
Assessment complete.