TITLE: 04/08 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY:
More vent work today. I was able to mark some things fully or partially done, but others I'm unaware of their current status
DONE FAC - 2nd Cleaning BSC8
DONE Investigate large shifts in trends of PRM and PR2 in YAW (83807, 83808)
DONE IAS - HAM1 Stack table survey
PARTIALLY JIM/MITCH - HAM1 Offload HEPI Setup, disconnect actuators
PARTIALLY ISC - HAM1 - ISC component removal
PARTIALLY VAC/FAC - BSC8 Door Off - CRANE to Caddy
VAC - Start Feedthru Swap
EE - HAM4-5 Cable tray work - Ken, some Crane usage
IAS - HAM1 support tube ends?
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 14:44 | FAC | Kim, Nelly | LVEA | n | Tech clean (HAM1, restock) | 17:26 |
| 14:56 | FAC | Eric | HAM Shack | n | Annual maintenance | 16:38 |
| 15:10 | Betsy | LVEA | n | Taking to FAC | 15:25 | |
| 15:23 | VAC | Jordan | LVEA | N | Dew point check | 15:36 |
| 15:34 | IAS | Jason, RyanC | LVEA | n | FAROing | 18:57 |
| 15:51 | VAC | Jordan, Melina | EX | n | Checking on ion pump | 16:22 |
| 15:52 | Betsy | OpticsLab | n | Prepping to recrimp cables | 16:55 | |
| 15:53 | FAC | Tyler | LVEA, HAM Shack | n | Checking on things | 19:07 |
| 16:25 | EE | Marc | CER | n | Grabbing label maker | 16:35 |
| 16:58 | Corey, Mitchell | MY | n | Grabbing tooling | 17:28 | |
| 17:01 | SUS | Betsy | LVEA | N | BSC8 Dust Count Check | 17:20 |
| 17:02 | FAC | Chris, Pest Control | LVEA | n | Pest control | 18:06 |
| 17:03 | TJ | Mech Room | n | Checking out dust monitors | 17:10 | |
| 17:08 | ISI | Jim | LVEA | n | Checking if HAM1 is ready | 17:45 |
| 17:12 | TJ | LVEA | n | Checking dust monitor | 17:44 | |
| 17:50 | FAC | Kim, Nellie | EX | N | Technical cleaning | 18:43 |
| 17:54 | SEI | Jim, Mitchell | LVEA | n | HAM1 work | 18:01 |
| 18:00 | VAC | Jordan, Melina, Travis | LVEA | n | Start removal of HAM6 turbo pump | 19:16 |
| 18:01 | Mitchell, Jim | HAM Shack | n | Looking for parts | 18:15 | |
| 18:06 | FAC | Chris | LVEA | N | Equipment check | 18:57 |
| 18:12 | PEM | Robert | LVEA | n | Talking to VAC | 18:34 |
| 18:13 | TJ | LVEA | N | Dust monitor test | 18:24 | |
| 18:15 | SUS | Jim, Mitchell | LVEA | N | HEPI Offload | 19:37 |
| 18:26 | ISC | Betsy, Camilla | LVEA | n | Prepping for stuff removal at HAM1 | 19:15 |
| 19:07 | Josh, Jeff, +2 | LVEA | n | Tour | 19:46 | |
| 19:42 | FAC | Travis, Jordan, Randy | LVEA | N | BSC8 Door move | 00:19 |
| 20:18 | ISC | Betsy, Elenna, Camilla | LVEA | n | Checking HAM1 layout discrepencies | 23:20 |
| 20:25 | Richard | LVEA | n | Walkabout | 22:28 | |
| 20:52 | FAC | Tyler, Alpine roofing | EY | n | Looking at roof | 21:44 |
| 20:58 | EE | Marc | CER | n | labeling | 21:44 |
| 20:59 | Mitchell, Jim | LVEA | n | HAM1 feedthrough | 23:27 | |
| 21:42 | TJ | LVEA | n | Talking about discrepencies | 21:58 | |
| 22:01 | VAC | Travis | MX/MY | N | Conflat blank | 22:29 |
| 22:04 | FAC | Ryan C | LVEA | N | Dust monitor check | 22:38 |
| 22:29 | Oli | LVEA | N | HAM1 deinstall help | 23:20 | |
| 22:30 | VAC | Travis | LVEA | N | Turbo Swap | 00:30 |
| 22:30 | FAC | Richard | LVEA | N | Walkabout + Headcount | 22:44 |
| 22:49 | FAC | Tyler, Water contractor | Water Tank | N | Continuing potable water restoration work | 00:49 |
| 23:35 | RyanC | LVEA | n | Checking on dust monitor | 00:05 |