WP12459 Prototype Estimator
Jeff K, Brian L, Edgar B, Jonathan H, Erik VR, Dave B
We installed new models for h1isiham2, h1isiham5, h1suspr3 and h1sussr3. DAQ restart was required.
WP12458 New ISI HAM1 Guardian nodes
TJ, Dave B
TJ installed four new guardian nodes, these were added to EDC and a DAQ restart was required.
DAQ Restart
Jonathan H, Dave B.
DAQ was restarted for model changes and EDC additions. Because we are in a vent we elected to do an old-fashioned restart whereby the Trend Writers are not turned off prior to the restart of the EDC in order to maximize the vacuum trend data stream. This does mean that systems following guardian in the edcumaster.txt file will see outliers when using NDS1.
Restart sequence was: 0-leg + EDC, then 1-leg when fw0 had restarted.
Here is a summary of the model changes:
h1isiham2
h1isiham5
h1suspr3
h1sussr3
Mon14Apr2025
LOC TIME HOSTNAME MODEL/REBOOT
13:53:40 h1seih23 h1isiham2
13:54:17 h1sush2a h1suspr3
13:54:50 h1seih45 h1isiham5
13:55:37 h1sush56 h1sussr3
13:56:56 h1daqdc0 [DAQ] <<< 0-leg restart
13:57:05 h1daqfw0 [DAQ]
13:57:05 h1daqtw0 [DAQ]
13:57:06 h1daqnds0 [DAQ]
13:57:14 h1daqgds0 [DAQ]
13:57:23 h1susauxb123 h1edc[DAQ] <<< EDC restart while 0-leg down
14:01:10 h1daqdc1 [DAQ] <<< 1-leg restart
14:01:17 h1daqfw1 [DAQ]
14:01:18 h1daqnds1 [DAQ]
14:01:18 h1daqtw1 [DAQ] <<< TW1 resyncs with new EDC config
14:01:25 h1daqgds1 [DAQ]
14:02:08 h1daqgds1 [DAQ] <<< GDS1 needed a second restart