Reports until 10:11, Tuesday 15 April 2025
H1 SUS
edgard.bonilla@LIGO.ORG - posted 10:11, Tuesday 15 April 2025 - last comment - 13:13, Tuesday 15 April 2025(83922)
Added an OSEM estimator folder to the sus SVN

Edgard, Oli, Brian.

We added a folder with a script that calculates the noise budget for the OSEM estimator for an HLTS.

The folder lives in: sus/trunk/HLTS/Common/FilterDesign/Estimator/.  

The script inside is called (at least for now) PR3_noise_budget.m, and it uses the simulink diagram in the same folder to run. The diagram doubles as a diagram for the estimator scheme itself, so it can be useful to look at.

We will post more commissioning scripts in this folder later in the week.

 

Comments related to this report
edgard.bonilla@LIGO.ORG - 13:13, Tuesday 15 April 2025 (83929)

Just ensured the noise budget runs in an operator machine. It needs access to the SusSVN, to the matlabtools folder of the SeiSVN, and access to the ISI2SUS projection matrices saved in /opt/rtcds/userapps/release/isc/common/projections/

The changes are current as of SusSVN revision 12226.