Matt, Elenna, Camilla
All individual optics removed from HAM1 have been inspected, cleaned and if needed swapped. Progress alogs: 83875, 83858.
The optics are in pans 1, 2 and 3. We still need to inspect the mirrors on the pericope and might swap more black glass beamdumps to DLC coated SS, but otherwise we are ready to install back into HAM1. Optics that were changed are noted below, this has been updated in the D1000313 googlesheet. All removed optics are stored with the other optics in the staging building.
|
Optic
|
Original
|
New
|
Note
|
|
M1
|
BS50%1064
E1000671-02
S/N 052
|
BS50%1064
E1000671-02
Note below *
|
Original Optic had specks on the center that couldn't be removed with FC
|
|
M10
|
HR1064HT532 E1000669
S/N 014
|
HR1064HT532
E1000669-v1
S/N 043
|
Original Optic had cluster of specks on the center that couldn't be removed with FC
|
|
M12
|
BS95%1064
E1000871-02
S/N 004
|
BS90%1064
E040512-B3
IO820-05
|
Changed 95/5 to 90/10 BS
|
|
M15
|
HR1064
E1100048
S/N 2.0-0990
|
BS50%1064
E040512-B1
S/N IO826-08
|
Swapped from HR1064 to 50/50BS, changed handedness, moved picos.
First BS optic we tried to use in 83858 had 1" thin line across, so swapped again.
|
* The M1 BS E1000671-02 had no S/N but the box was labeled with Coating Run 515074 & 315079 and datasheet. We scrubbed the pencil mark off the barrel so it's barely visible, but the coated side was above the writing, see photo attached.