Reports until 09:15, Wednesday 06 November 2013
H1 CDS
james.batch@LIGO.ORG - posted 09:15, Wednesday 06 November 2013 (8395)
Restarted h1sush34, DAQ
Found h1sush34 frozen following an attempt at restarting user models (yesterday evening).  This caused mx-stream issues which affected most front-ends in the corner station.  I removed h1sush34 from the dolphin network and power cycled it. As soon as the computer restarted, the mx-stream errors went away.  

Following this, several models had a 0x2000 status left over from installation of modified models, so I restarted the DAQ (at 9:01 PST).