Jim, Tony, Dave:
We restarted h1isiham1 model four times and the DAQ twice:
1. Internal wiring change to model, no DAQ retstart for that but new common part with "missing ADC chans" fix was included which did require a DAQ restart. No issues with DAQ restart other than gds0 needed a second restart.
2. A copy-paste binary parts issue was found, HAM6 parts were included in HAM1. BIO parts were renamed, no DAQ restart was neeed.
3. HAM1 differs from HAM6 in BIO inputs in that it reads 64 input channels instead of just 32. Upper32 channel BIO part was added, which added slow channels, so DAQ restart was required. No issues with DAQ restart other than gds0 second restart.
4. To minimize binary chassis hardware, HAM1 and HAM6 share the first BIO card's binary output chassis, HAM6 uses lower 32 chans, HAM1 uses upper 32 chans. h1isimodel was changed to use BIO-0 U32 for outputs. No DAQ restart was required.
Current BIO hardware as see by models:
wiring | input block | model | model | output block | wiring | |
from ham6 | BIO-0 low 32 | h1isiham6 | h1isiham6 | BIO-0 low 32 | to ham6 | |
not connected | BIO-0 high 32 | none | h1isiham1 | BIO-0 high 32 | to ham1 | |
from ham1 | BIO-1 low 32 | h1isiham1 | none | BIO-1 low 32 | no chassis | |
from ham1 | BIO-1 high 32 | h1isiham1 | none | BIO-1 high 32 | no chassis |
DAQ Changes
1st DAQ restart (correct missing ADC chans)
++: slow channel H1:ISI-HAM1_PMON_GS13_P3_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_GS13_P2_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_GS13_P1_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_GS13_D3_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_GS13_D2_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_GS13_D1_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_P3_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_P2_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_P1_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_D3_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_D2_CTS added to the DAQ
++: slow channel H1:ISI-HAM1_PMON_FF_L4C_D1_CTS added to the DAQ
2nd DAQ restart (read H32 BIO-1 channels)
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_H1_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_H2_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_H3_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_V1_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_V2_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_GAIN_L4C_V3_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_INMON2 added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_TEST2 added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_TESTMON2 added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_H1_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_H2_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_H3_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_V1_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_V2_RB added to the DAQ
++: slow channel H1:ISI-HAM1_BIO_IN_WHT_L4C_V3_RB added to the DAQ
Thu17Apr2025
LOC TIME HOSTNAME MODEL/REBOOT
09:09:41 h1seih16 h1isiham1 <<< model restart, fix wiring, add missing-adc-chans
09:12:10 h1daqdc0 [DAQ] <<< 0-leg
09:12:20 h1daqfw0 [DAQ]
09:12:21 h1daqtw0 [DAQ]
09:12:22 h1daqnds0 [DAQ]
09:12:29 h1daqgds0 [DAQ]
09:13:19 h1daqgds0 [DAQ] <<< 2nd gds0 restart
09:16:23 h1daqdc1 [DAQ]
09:16:33 h1daqfw1 [DAQ] <<< 1-lde
09:16:34 h1daqtw1 [DAQ]
09:16:35 h1daqnds1 [DAQ]
09:16:44 h1daqgds1 [DAQ]
10:10:21 h1seih16 h1isiham1 <<< model restart, change bio address
10:27:28 h1seih16 h1isiham1 <<< model restart, add BIO-1 H32
10:32:12 h1daqdc0 [DAQ] <<< 0-leg
10:32:23 h1daqfw0 [DAQ]
10:32:24 h1daqtw0 [DAQ]
10:32:26 h1daqnds0 [DAQ]
10:32:32 h1daqgds0 [DAQ]
10:35:28 h1daqgds0 [DAQ] <<< 2nd gds0 restart
10:36:21 h1daqdc1 [DAQ] <<< 1-leg
10:36:32 h1daqfw1 [DAQ]
10:36:32 h1daqtw1 [DAQ]
10:36:34 h1daqnds1 [DAQ]
10:36:42 h1daqgds1 [DAQ]
10:57:48 h1seih16 h1isiham1 <<< model restart, drive BIO-0 H32
Two more h1isiham1 model restarts, the first with an associated DAQ restart.
14:35 h1isiham1 binary output block was upgraded, adding slow channels to the DAQ. During DAQ restart gds0 and gds1 needed second restarts.
15:53 h1isiham1 input bus selector to binary output block was corrected, no DAQ restart needed.
14:35:41 h1seih16 h1isiham1 <<< new binary output block
14:37:30 h1daqdc0 [DAQ] << 0leg
14:37:40 h1daqfw0 [DAQ]
14:37:40 h1daqtw0 [DAQ]
14:37:41 h1daqnds0 [DAQ]
14:37:48 h1daqgds0 [DAQ]
14:38:22 h1daqgds0 [DAQ] <<< 2nd gds0 restart
14:41:43 h1daqdc1 [DAQ] <<< 1leg
14:41:54 h1daqfw1 [DAQ]
14:41:54 h1daqtw1 [DAQ]
14:41:55 h1daqnds1 [DAQ]
14:42:03 h1daqgds1 [DAQ]
14:43:00 h1daqgds1 [DAQ] <<< 2nd gds1 restart
15:53:57 h1seih16 h1isiham1 <<< correct input bus of binary output block