J. Oberling, J. Warner
After letting things settle overnight we took another look at the WHAM1 ISI alignment this morning. Jim found that a few of the HEPI stops had become engaged (likely during the final moves yesterday afternoon), so he backed those off and I took a look at ISI alignment. Again, the ISI position is reported as deviation from its nominal LHO global coordinates of [-22726.7, 0.0, -201.9] mm.
Jim said this was good enough to begin attaching HEPI actuators, so that work has begun. We'll take another look at ISI alignment once the actuators are attached.