Reports until 11:07, Wednesday 30 April 2025
H1 ISC (SEI)
ryan.crouch@LIGO.ORG - posted 11:07, Wednesday 30 April 2025 - last comment - 13:05, Wednesday 30 April 2025(84196)
HAMs 2, 3, 4, 5 HEPI yaw angles

I took a look at the YAW angle for the HAM HEPIs associated with PR2 (incorrect by me) (HAM2), SR2 (HAM4), and SR3 (HAM5) based on this previous alog83705. I believe the IPS channel units are in nrad, so the largest yaw angle I see is on HAM2 with 1800 nrad or 1.80 urad, HAM2 and 4 are different by ~ 1.10 urad.

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 12:19, Wednesday 30 April 2025 (84199)

I added on the RESIDUALMON channels at Jims recommendation which directly tells you the error from the reference location.

Images attached to this comment
ryan.crouch@LIGO.ORG - 13:05, Wednesday 30 April 2025 (84202)

Here's HAM3, 0.392 urad as seen by HEPI

Images attached to this comment