Reports until 11:08, Friday 08 November 2013
H1 PSL (PSL)
stefan.ballmer@LIGO.ORG - posted 11:08, Friday 08 November 2013 - last comment - 13:08, Friday 08 November 2013(8440)
PMC (and whole PSL) working again
(Richard, Stefan)

After some tail chasing (which included verifying that the spare PMC board works too), we found the 35MHz PMC EOM feed cable ripped out of the connector.
Fixing this obviously restored all PSL functionality. A better connector is currently being installed.

I also did a burt-restore to 10/26/2013 9am UTC (back when it was still working) to make sure we didn't pick up any spurious settings.

Comments related to this report
stefan.ballmer@LIGO.ORG - 13:08, Friday 08 November 2013 (8443)PSL
Phil fixed the connector - the PMC is now working again.

The EOM cable length changed by maybe 2in in the process - we did not re-phase it now because the beam is needed for HAM2 work.