Displaying report 1-1 of 1.
Reports until 02:45, Friday 16 May 2025
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 02:45, Friday 16 May 2025 (84423)
HAM1 Vacuum Work, Installation Of A New Gauge and Turbo Pump

(Jordan V., Travis S., Gerardo M.)
Today we installed a new gauge on the 16.5" conflat on top of HAM1, installed on the top central port, D1.  A single gauge replaces a gauge pair combo, pirani and cold cathode, this gauge will be used for the high voltage interlock system for HAM1.  The gauge still needs the installation a couple of cables for it to work.

The turbo pump was the second item that was replaced on HAM1, an outdated and noisy turbo pump was removed and replaced with a new turbo pump.  No issues were encountered during the removal or installation of the new pump.

All of the affected conflats will need to be checked for leaks.

Images attached to this report
Displaying report 1-1 of 1.