Displaying report 1-1 of 1.
Reports until 16:30, Friday 16 May 2025
H1 General (SUS)
oli.patane@LIGO.ORG - posted 16:30, Friday 16 May 2025 - last comment - 17:06, Friday 16 May 2025(84440)
Ops Day Shift End

TITLE: 05/16 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY:

Work is ongoing in HAM1 to finish up all the checks we need done before doors go on next week.

The RM/PM damping issues that we've been seeing (84427) are most likely due to the higher purge air in HAM1 since they had been working fine two days ago when the purge air had been turned way down, and yesterday and today when the purge air had been turned up, were not working. We'll be able to better confirm this on Monday during a time when we can have the purge air very low and there isn't any activity happening in HAM1. RM1, RM2, and PM1 have been put into SAFE for the weekend.

The LVEA is currently LASER HAZARD.

Sensor correction is on in the LVEA (SEI_ENV: LIGHT_MAINTENANCE_WINDY and SEI_CONF: NOBRSXY_WINDY).
LOG:

Start Time System Name Location Lazer_Haz Task Time End
14:52 FAC Kim LVEA YES Tech clean 15:40
15:28 ISC Sheila LVEA YES Transitioning to laser hazard 15:42
15:28 VAC Jordan LVEA YES Purge air checks 15:44
16:01 ISC Sheila LVEA YES Turning off a sideband 16:08
16:36 ISC Marc, Sheila LVEA YES Turning on HV for HAM6 16:41
16:37 VAC Janos LVEA YES Checking things 16:45
17:10 ISC Sheila LVEA YES Turning sidebands back on 17:26
17:53 ISC Sheila, Elenna LVEA YES Final beam checks in HAM1 20:13
20:04 SEI Michael, Shoshana EY n Minor wiring on BRS 20:47
20:14 VAC Jordan MX n Vacuum measurements 21:46
20:47 PEM Robert LVEA YES Looking for scattered light in HAM1 21:57
21:46 VAC Jordan LVEA YES Vacuum measurements 21:57
21:55 TCS Tony & Mitchel Mech room N Chiller water checks. 22:06
22:07 CDS Oli, Marc CER YES Checking out PM1 coil drivers 22:14
22:16 ASC Sheila & Elenna LVEA HAM1 Yes Final Beam Checks. ongoing
22:43 VAC Jordan LVEA YES Turning HAM1 purge air down 22:46
23:13 VAC Jordan LVEA YES Turning purge air back up 23:14
Comments related to this report
elenna.capote@LIGO.ORG - 17:06, Friday 16 May 2025 (84444)

Just adding a note:

As of the end of the day, Sheila and I have left the sidebands OFF, and the HAM6 high voltage ON (per WP #12545).

Displaying report 1-1 of 1.