Displaying report 1-1 of 1.
Reports until 10:33, Friday 16 May 2025
H1 ISC
jennifer.wright@LIGO.ORG - posted 10:33, Friday 16 May 2025 - last comment - 11:40, Tuesday 03 June 2025(84432)
OMC scans with SR3 heater on

Jennie W, Sheila, Elenna

 

In order to get data for mode-matching and for Elenna to get data to calibrate sideband heights we ran some mode scans after the SR3 heater was turned on last night.

16:55:24 UTC Carried out single bounce OMC scan at 10W PSL input with sensor correction on HAM6 on, high voltage on for PZT driver in HAM6, sidebands off , SRM mis-aligned, ITMY mis-aligned, DC 3 and 4 on, OMC ASC on.

Excitation freq changed to 0.005 Hz as the top peak of the TM00 mode looked squint so could have been saturating. Lowering this frequency prevented this.

Ref 15-17 corresponds to dcpd data, pzt exc signal, pzt2 dc monitor.

 

Then mis-aligned ITMX and aligned ITMY (Sheila had to re-align SR2 to centre on ASC-AS_C).

Measurement starts at 17:08:18 UTC.

Ref 18-20 corresponds to dcpd data, pzt exc signal, pzt2 dc monitor.

 

Traces saved in 20250516_OMC_scan.xml. The top left plot is the first scan bouncing beam off ITMX, the second scan is the bottom right bouncing off ITMY.

The top right is the two plots of the PZT2 DC voltage monitor. That is, the current voltage applied to the PZT. The bottom left is the plot of the voltage ramp applied to the PZT2 on the OMC for this measurement.

 

The ndscope attached shows the power in mA transmitted through the OMC on the top, then the PZT used for the scan DC voltage underneath, then the input PZT voltage underneath that, then the reflected power from the OMC in mW, then at the bottom the SR3 heater element temperature in degrees.

 

Elenna did two more scans in single bounce with sidebands back on and different modulations depths in each.

Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 10:38, Friday 16 May 2025 (84433)

See Elenna's comment on her previous measurement where this saturation happened.

Turn off the sidebands - instructions in this alog.

elenna.capote@LIGO.ORG - 16:51, Friday 16 May 2025 (84441)

Sheila and I ran one more OMC scan with sidebands off after OM2 heated up. Attached is the screenshot with scans off both ITMX and ITMY, data is saved in [userapp]/omc/h1/templates/OMC_scan_single_bounce_sidebands_off.xml

 

Images attached to this comment
elenna.capote@LIGO.ORG - 17:02, Friday 16 May 2025 (84442)

I also ran two OMC scans, single bounce off ITMY, 10 W input, with the sidebands ON. One measurement I ran with the sidebands set to 23 dBm and 27 dBm (9 and 45 MHz) and another set to 20 dBm and 21 dBm (9 and 45 MHz). I will use these measurements to calibrate the modulation depth. Data saved in /opt/rtcds/userapps/release/omc/h1/templates/OMC_scan_single_bounce_RF_cal.xml

SR3 heater was on for this measurement but it should have little effect on my results.

camilla.compton@LIGO.ORG - 11:40, Tuesday 03 June 2025 (84749)

Looked closer at these HWS signals during SR3 heater heat up and cool down. In all these plots, the two t-cursors are used as the reference and shown HWS live image.

  • Heat up plot attached
  • Cool down plot attached (ITMX was misaligned so there's no HWS data)

Some strange things:

  • ITMX heat up ndscope spherical power looks the opposite direction of ITMY, this isn't physical. Looking at the HWS Live plot, this isn't really want's happening, it appears that the SR3 signal just appears if the edge of ITMX is heating up so the center that the calculations are made from isn't correct, making the calculated spherical power wrong.
  • In both the heat up and cool down of the ITMY signal, there appears to be two steps with a flat region in the middle. Looking at the the flat region only, attached, it appears that the spherical power is continuing to change in the expected direction, unsure why this change isn't shown in the calculated spherical power.
Images attached to this comment
Displaying report 1-1 of 1.