Reports until 15:27, Friday 08 November 2013
H1 SEI (CDS, SEI)
hugo.paris@LIGO.ORG - posted 15:27, Friday 08 November 2013 (8447)
HEPI Science frame Channels Added

Adjusted channel names in the master model of HEPI so channels would be recorded in the science frame - Per E1300742

Commited the new master model (hepitemplate.mdl)  -r6229

Every HEPI model of H1 (11) was restarted.

Restarting HEPI-HAM2, and then the DAC added 25 channels to the science frame, as expected.

Restarting HEPI HAM3, HAM4, HAM5, HAM6, ETMX, ITMX, BS,ITMY, ETMY, and then the DAC, added 225 (9*25) to the science frame.

Work was performed under WP# 4256 which is now closed.This was performed in the scope of Bugzilla bug #385

Details are attached in log file.

Images attached to this report
Non-image files attached to this report