HAM1 pressure has already gone below the threshold that we consider the suspensions to stop floating, so I've taken in vac transfer functions for RM1, RM2, and PM1. All three suspensions are looking healthy.
Earlier today, Fil completed the coil driver swap for PM1 (84490), so I updated the COILOUTF filters(84499), and now all filters (physical and digital) match the ones for the RM coil drivers (84499).
Note that these were taken with the ISI locked and HEPI offline.
RM1 (r12326(data), r12327(results)):
Data: /ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/RM1/SAGM0/Data/2025-05-21_0000_H1SUSRM1_M1_WhiteNoise_{L,P,Y}_0p01to50Hz.xml
RM2 (r12329):
Data: /ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/RM2/SAGM0/Data/2025-05-21_0015_H1SUSRM1_M1_WhiteNoise_{L,P,Y}_0p01to50Hz.xml
PM1 (r12328):
Data: /ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/PM1/SAGM0/Data/2025-05-20_2200_H1SUSRM1_M1_WhiteNoise_{L,P,Y}_0p01to50Hz.xml
Results: /ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/PM1/SAGM0/Results/2025-05-20_2200_H1SUSRM1_M1*
Comparison of all three HTTS (r12330):