Reports until 18:04, Tuesday 20 May 2025
H1 SUS
oli.patane@LIGO.ORG - posted 18:04, Tuesday 20 May 2025 (84499)
PM1 COILOUTF filters fixed fixed

Yesterday I fixed the PM1 COILOUTF filters because we had accidently copied in filters from the RMs, which had a different coil driver set up due to an ECR that hadn't yet been done for PM1, so I corrected them (84455). Today, Fil changed out the PM1 coil driver so it now is correct as per ECR E2200307 and E2400048 (84490), so I've re-re-placed the PM1 coil driver filters with the now correct same filters that the RMs have. I've loaded them in.