PCAL Y-End TX module maintenance

 Y-End TX Module Maintenance was performed today.
Everything went fairly well while following the instructions laid out in T1600436 -V12 Except the AOM Rejected Power measurement. This measurement inbetween PBSC2 and beam dump 2  is measuring the AOM power that we were dumping on to the beam dump. It didn't ever give us a static value like all the rest of the measurements. The max was a 18.5 mW  jump right after the we opened the shutter. Then the power would decay down to a lower value of 13.6 mw but over several minutes. The decay rate seemed to get longer after a while. The excitations were indeed turned off. We had zeroed the low power sensor with a shuttered background measurement. I'm not sure why that seemed to not be a steady number. We ended up taking the number that seemed like it had initially asymptote to before we saw the slow fall off.

The Beam Spots all look great. TX Sphere might be very slightly  to the right of perfectly center, but I think it's fine.
 

OLTF went well, Setup was well documented.

   
Date May , 21,2025
Laser Shutter Check pass
Max OFS Offset 8
95% OFS Offset 7.6
Operating OFS Offset 3.8
Laser Output Power 1.94 W
After-Laser Rejected Power 4.11 mW
AOM Input Power 1.91 W
Max Diffracted Power 1.60 W
Un-Diffracted Power 0.285 W
AOM Diffraction Efficiency 83.77%
After-AOM Rejected Power 15.5 mW
TxPD Power 6.51mW
OFSPD Power 6.64 mW
Outer Beam Power 0.355 W
Inner Beam Power 0.352 W
Output Beam Power Ratio 0.991549295774648
OFS Gain 38.5
OFS Phase Margin 58
Images attached to this report
Non-image files attached to this report
Comments related to this report
anthony.sanchez@LIGO.ORG - 17:08, Wednesday 21 May 2025 (84529)

Updated the safe.snap files...... but not the observe.snap files because when loaded there were not any changes. because the files are linked and i had already saved the changes in the safe.snap file.

 